from 1” pipe, wall thickness from 2,77mm and up. Material C/S-Duplex-Super Duplex-316 and 6Mo. Titanium 4mm plate.
Bolt inspection from M12
Corrosion under pipe support
TOFD
Time of flight diffraction ultrasonic testing (UT) is typically used in conjunction with a a phased-array application as a rapid screening tool for the detection and sizing of circumferential- and axial-weld imperfections.
SLOFEC
Saturated low frequency eddy current corrosion-inspection technology for storage tank floor, pipe and vessel inspections.
IRIS
Internal rotating inspection system is a technique that can be applied to both ferrous and non-ferrous materials. Local defects and wall loss on both sides of the tube can be accurately measured.
AUT
Automated ultrasonic inspection is to carry UT NDT welding inspection of girth welds during the construction of long-distance pipelines.
FLOW PIG
DTI Trekscanners facilitating ultrasonic testing of pipelines from 3’’ and up, up to 50 km length.