Dimensions

  • Length(mm):
    1800
  • Width(mm):
    1200
  • Height(mm):
    1700
  • Weight (kg):
    1170
  • Lifting/ Transportation:
    Frame with forklift channels and lifting slings. DNV 2.7-1.

Construction year

  • Built:
    1994
  • Upgraded/rebuilt:
    2010

Area of use / certification

  • Onshore/offshore:

    Offshore

Flow / Pressure / Volume

  • Tank Volume (ltr):
    200
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    45
  • Hz v P-max measure:
    60
  • P-max (bar):
    410
  • Max temp. (GrC):
    60

Connections

  • Inlet connection:
    ½" BSP
  • Outlet connection:
    ½" BSP

Pump(s)

  • Pump1 (type):
    Harben 8.18 High Lift
  • Pump1 (Cert. No.):
    19780

Motor / Engine(s)

  • Motor1 (type):
    ATB BD 200L2-6 II2G EEx de IIB T4 Cert. No: PTB 99 ATEX 1091
  • Motor1 (Cert. No.):
    445926001

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    400 VD
  • (Hz):
    50
  • (kW):
    22
  • (A):
    41,5
  • El.Power2:
    400 VD
  • (Hz):
    60
  • (kW):
    22
  • (A):
    41,5
  • El.Power3:
    440-480 VD
  • (Hz):
    60
  • (kW):
    26
  • (A):
    44,5-40,5
  • El.Power4:
    690 VY
  • (Hz):
    50
  • (kW):
    22
  • (A):
    24,0
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    22
  • (A):
    25,0-24,0
  • Starter:

    Stahl 8225/122 0 (Ser. No: 79553)

    EEx de IIC T5 (PTB No: Ex-91.C.1064U)

    400-690 V Max load: 41 A 50-60 Hz

Filter

  • Inlet filter (qty):
    1
  • Inlet filter house (type):
    Parker
  • Inlet filter element (type):
    D142G03A

Additional information

  • Equipment / Functions:

    Level glass, flowmeter, heat exchanger, thermometer, safety valve, Steamloop / Tub cooler

    Can also be used as a flushing unit for water, glycol and oil (when using external filters). Possible to flush unit internally