Dimensions

  • Length(mm):
    2000
  • Width(mm):
    1200
  • Height(mm):
    2030
  • Weight (kg):
    3000
  • Lifting/ Transportation:

    Frame with forklift channels and lifting slings. DNV 2.7-1.

Construction year

  • Built:
    2013

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eex de IIB T4 Zone 1, Norsok Z-015

Flow / Pressure / Volume

  • Tank Volume (ltr):
    300
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    31
  • Hz v P-max measure:
    60
  • P-max (bar):
    415
  • Max temp. (GrC):
    60

Connections

  • Inlet connection:
    ½" BSP Connection tank: ¾" BSP male
  • Outlet connection:
    ½" BSP

Pump(s)

  • Pump1 (type):
    Harben 8.18 P type with HW valves
  • Pump1 (Cert. No.):
    23815

Motor / Engine(s)

  • Motor1 (type):
    ATB BD 225M-6 II2G EEx de IIB T4

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    400-690 VD
  • (Hz):
    50
  • (kW):
    30
  • (A):
    56,0-32,4
  • El.Power2:
    400 VD
  • (Hz):
    60
  • (kW):
    30
  • (A):
    56,0
  • El.Power3:
    440-480 VD
  • (Hz):
    60
  • (kW):
    35
  • (A):
    560,0-55,0
  • El.Power4:
    660-690 VY
  • (Hz):
    60
  • (kW):
    30
  • (A):
    35,0-32,0
  • Starter:

    Ceag (Ser. No: GHG6401905R001)

    EEx de IIB T4

    400-690 V Max load: 60 A 50-60 Hz

Filter

  • Outlet filter (qty):
    1
  • Outlet filter house (type):
    Donaldson P164598 / D143G03A
  • Outlet filter element (type):
    P169435
  • Inlet filter (qty):
    1
  • Inlet filter house (type):
    Parker FH2 5L 100 bar 85A
  • Inlet filter element (type):
    Donaldson P164598 / D143G03A

Additional information

  • Equipment / Functions:

    FUSE RATING:

    660-690V: 63 A

    400-480V: 63 “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)

    Equipment/features :

    Sight gauges, flow meter, pressure and return filters, thermometer, safety valve, fluid cooler and high level in tank.

    Can also be used as hydrojetting and chemical cleaning with fluid up to 60grC.