COMPACT UNIT FOR CHEMICAL CLEANING
Construction year
-
Built:
2002
-
Upgraded/rebuilt:
2022
Area of use / certification
Flow / Pressure / Volume
-
Tank Volume (ltr):
350
-
Hz v Q-max measure:
60
-
Q-max (l/min):
40
-
P-max (bar):
300
Connections
-
Inlet connection:
1/2" BSP
-
Outlet connection:
1/2" BSP
Motor / Engine(s)
-
Motor1 (type):
Teve Varnost 4KTC200L-4
II2G EEx de IIC T4
PTB 05 ATEX 1099
-
Motor1 (Cert. No.):
200830712
Power supply
-
Fuse (qty):
1
-
Fuse (A):
63A
-
El.Power1:
380-415 VD
-
(Hz):
50
-
(kW):
30
-
(A):
53,0
-
El.Power2:
660-720 VS
-
(Hz):
50
-
(kW):
30
-
(A):
31,0
-
El.Power3:
380-415 VD
-
(Hz):
60
-
(kW):
30
-
(A):
54,6
-
El.Power4:
440-480 VD
-
(Hz):
60
-
(kW):
34,5
-
(A):
53,3
-
El.Power5:
660-690 VS
-
(Hz):
60
-
(kW):
30
-
(A):
31,5
-
Starter:
MES Type 22-002
Snr 2200113-001
II2(1)G Ex db eb [ia Ga] IIC T4 Gb
Filter
-
Outlet filter house (type):
FH2,4L420BAR-85-A
-
Outlet filter element (type):
P164598
-
Inlet filter (qty):
1
-
Inlet filter house (type):
FH2,5L100BAR-85-A
-
Inlet filter element (type):
P164598
Additional information
-
Equipment / Functions:
Heat exchanger, flowmeter, outlet for samples, manhole cover in tank.
The unit is built in acid-resistant material.
The unit is built especially for chemical cleaning of tubing.
660-690V: 63 A
400-480V: 63 “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)