Dimensions

  • Length(mm):
    3200
  • Width(mm):
    1250
  • Height(mm):
    1800
  • Weight (kg):
    2300
  • Lifting/ Transportation:
    Frame with lifting chain and forklift channels in acc. to DNV 2.7-1

Construction year

  • Built:
    2007

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIB T4 Zone 1, in acc. to Norsok Z-015

Flow / Pressure / Volume

  • Tank Volume (ltr):
    800
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    2500
  • Hz v P-max measure:
    60
  • P-max (bar):
    8.5

Connections

  • Inlet connection:
    2 ea. 2" Camlock Female
  • Outlet connection:
    2 ea. 2" Camlock Male

Pump(s)

  • Pump1 (type):
    Mega MCPK 100-065-200 CC
  • Pump1 (Cert. No.):
    997489934200010001

Motor / Engine(s)

  • Motor1 (type):
    F&G EExde IIB T4 type: BD250M-2 Multipower IP56, IM:B3, S1, 3000/3600rpm Standard painting RAL5009, II 2 G EExde IIBT4

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    125
  • El.Power1:
    400 VD
  • (Hz):
    50
  • (kW):
    55
  • (A):
    95
  • El.Power2:
    690 VY
  • (Hz):
    50
  • (kW):
    55
  • (A):
    55
  • El.Power3:
    400 VD
  • (Hz):
    60
  • (kW):
    55
  • (A):
    97
  • El.Power4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    64
  • (A):
    101-93
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    55
  • (A):
    59-56
  • Starter:

    CEAG GHG 6655 (Ser. No: J06 0899 /D/M)

    II2G EEx de IIC T6 (Cert. No: PTB 98 ATEX 1054U)

    Nemko No: 06 ATEX 2380

  • Heater:
    Norske Backer IH-Ansi 6”-1000DL (Nemko No: 04 ATEX 1489) 52 kW 3x480V (Recommended back up fuse 63A (Voltage range (400-690 50/60Hz))

Filter

  • Inlet filter (qty):
    4
  • Inlet filter house (type):
    Bagfilter (w/4 bag) Type Parker 6SB42-4FK1,SS316
  • Inlet filter element (type):
    C2P5

Additional information

  • Equipment / Functions:

    Recommended back up fuse:

    Motor: 125A

    Heater: 63A (Voltage range (400-690 50/60Hz)

    Flow switch, steamloop, manhole cover in tank, flowmeter, heater

    Entire unit is built in acid-resistant material.