Dimensions

  • Length(mm):
    2155
  • Width(mm):
    1000
  • Height(mm):
    1690
  • Weight (kg):
    1450
  • Lifting/ Transportation:
    Frame with forklift channels and wheels (Ref. cert. frame : PU-28)

Construction year

  • Built:
    2008

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Z-015 (type):
    U99
  • Standard:
    Z-015, Zone 1 ATEX, II2G EEx cde IIC T4

Flow / Pressure / Volume

  • Tank Volume (ltr):
    360
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    98
  • Hz v P-max measure:
    50
  • P-max (bar):
    140
  • Flowrate1:
    Alternative Pump Head: 57 ltr/min / 267 Bar (@50Hz)
  • Max temp. (GrC):
    60

Connections

  • Inlet connection:
    1 ea. 1/2" BSP
  • Outlet connection:
    1 ea. 1/2" BSP

Pump(s)

  • Pump1 (type):
    Cat 6821DEx, Ex II 2Gc T4X
  • Pump1 (Cert. No.):
    PTB06 ATEX D 155

Motor / Engine(s)

  • Motor1 (type):
    ATB / F&G BD200L-4 II2G II2G EExde IIB T4 IP56 (Cert. Nr. PTB 99 ATEX 1091)
  • Motor1 (Cert. No.):
    480018001

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    400 VD
  • (Hz):
    50
  • (kW):
    30,0
  • (A):
    53
  • El.Power2:
    440-480 VD
  • (Hz):
    60
  • (kW):
    34,5
  • (A):
    55-51
  • El.Power3:
    400 VD
  • (Hz):
    60
  • (kW):
    30,0
  • (A):
    52
  • El.Power4:
    690 VY
  • (Hz):
    50
  • (kW):
    30
  • (A):
    31
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    30
  • (A):
    32-30
  • Starter:
    Trade Tech Ceag GHG 6645 (Ser. No. 08-002) EEx de IIC T6 (Cert. no. Nemko 08ATEX2009)

Filter

  • Outlet filter (qty):
    1
  • Outlet filter house (type):
    AD-D002185-WP420-DP420-TP600
  • Outlet filter element (type):
    D143G03A
  • Inlet filter (qty):
    1
  • Inlet filter house (type):
    AD-D004359-WP100-DP100-TP150
  • Inlet filter element (type):
    D143G03A

Additional information

  • Equipment / Functions:

    UNIT CAN BE DELIVERED WITH ALTERNATIVE PUMPHEAD (specify when ordering)

    CAPACITY FOR ALTERNATIVE PUMPHEAD: 57 ltr/min / 267 Bar (@50Hz)

    Recommended fuse:

    660-690V: 63 A

    400-480V: 63 “slow” fuse (D-characteristic, outlet for motorstarter, circuitbreaker)

    Heater Exchanger, flowmeter, sample-outlet, manhole on top of tank, level-glass, levelguard, pressureregulator, thermostat, safety valve

    Frame built in SS304, all wet parts in SS316.