COMPACT UNIT FOR CHEMICAL CLEANING
Area of use / certification
Flow / Pressure / Volume
-
Tank Volume (ltr):
1000
-
Hz v Q-max measure:
60
-
Q-max (l/min):
2000
-
P-max (bar):
7.5
Connections
-
Inlet connection:
3 ea 2” Female NPT
-
Outlet connection:
3 ea 2” Female NPT
Pump(s)
-
Pump1 (type):
Pentair, PWT-65-250S
Power supply
-
Fuse (qty):
1
-
Fuse (A):
80
-
El.Power1:
415-440 V
-
(Hz):
50/60
-
(A):
78,5
-
Starter:
Star-Delta Start
Filter
-
Inlet filter (qty):
2
-
Inlet filter element (type):
Filterbag
Additional information
-
Equipment / Functions:
Flow directional control.
Frame in Carbon Steel, all wet parts in Stainless Steel