Dimensions

  • Length(mm):
    6058
  • Width(mm):
    2438
  • Height(mm):
    2745
  • Weight (kg):
    14500
  • Lifting/ Transportation:
    20' Offshore container with lifting sling and forklift pockets. DNV 2.7-1 Ref. cert./Ser no. frame: 20863

Construction year

  • Built:
    1999

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Z-015 (type):
    G
  • Standard:
    Eexde IIA T3, Zone 2, 80dBa
  • Power (Electrical/Diesel):

    Diesel

Flow / Pressure / Volume

  • Water Supply:
    Via pulse dampener with 2-7 bar feed-water pressure.
  • Hz v Q-max measure:
    N/A (Diesel)
  • Q-max (l/min):
    188
  • Hz v P-max measure:
    N/A (Diesel)
  • P-max (bar):
    1000
  • Diesel Tank Volume (ltr):
    500
  • Diesel consumption (ltr/hr):
    100

Connections

  • Inlet connection:
    1 ea. 2" Fire coupling / Nor lock 1 1 ea. 2” Camlock Male (Connection water for cooling)
  • Outlet connection:

    1 ea. M24

    1 ea. M36 (2" BSP male at 600 l set)

    1 ea. 2" camlock Male (by-pass)

    1 ea. 2” Camlock Female (Connection water for cooling)

Pump(s)

  • Pump1 (type):
    Kamat type K35036A
  • Pump1 (Cert. No.):
    134651

Motor / Engine(s)

  • Motor1 (type):
    Scania type DSI 14 73 variant M40 S, 500 HP
  • Motor1 (Cert. No.):
    5565324

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    16
  • El.Power1:
    230 V (utility)
  • (Hz):
    50/60
  • Control Panel:
    Fire/Gas central : Technor Eexde IIB T5 Ser. no. 960620-1 230 V 1 phase 50/60 Hz

Additional information

  • Equipment / Functions:

    CAN BE DELIVERED WITH ALTERNATIVE PUMP HEAD: Q.max 600 ltr/min - P.max 300 bar

    Fixed fire extinguiser PEFS Foam.

    Fire extinguisher 12kg.

    - Signal to platform : Fire, gas and error alarm.

    - The pump has reduction-gear and air operated clutch.

    - Heater and emergency light.

    Air/Diesel supply shut down if:

    - Over racing of motor.

    - High temperature on exhaust.

    - High temperature on cooling liquid.

    - Low oil pressure on motor.

    - Low air pressure.

    - 10% LEL Gas alarm.

    - Fire alarm (flame)

    - Emergency shut-down.

    - Emergency shut-down from control room.

    - Feed-water pressure under 2 bar.

    - Low oil pressure on pump.