Area of use / certification
-
Onshore/offshore:
-
Standard:
Eexde IIA T3, Zone 2
Flow / Pressure / Volume
-
Q max (SCF/H):
180000
-
P-max (bar):
690
-
Diesel Tank Volume (ltr):
500
-
Diesel consumption (ltr/hr):
100
Connections
-
Inlet connection:
1 ea. Acme 150
-
Outlet connection:
1 ea. 1" Weco Fig. 1502
Pump / Engine
-
Triplex pump:
NS-181-NF.
CS&P Cryogenics 1,375" x 1,625"
-
Boost pump:
CS&P Cryogenics 1,5" x 2,5" x 6"
-
Cold-ends:
CS&P Cryogenics 1,625"
-
Vaporizer:
CS&P Cryogenics
-
Motor:
Detroit diesel 8V-92TA 480 HP, max. 2100 revolutions
IIA T3 Zone II
-
Motor (serial no.):
08VF172842
-
Filter LIN suction side:
Washable strainer
-
Fire /Gas central:
Stahl Eexde IIC T5 (Ser. no. 84382)
230 V 1 phase 50/60 Hz
-
Signal to platform at:
Gas alarm
-
Air/Diesel shut down at:
- Over racing of motor.
- High temperature on exhaust.
- High temperature on cooling liquid.
- Low oil pressure on motor.
- Low air pressure.
- Gas alarm.
- Emergency shut-down.
- Emergency shut-down from control room.
- Overpressure nitrogen.
Power supply
-
Fuse (qty):
1
-
Fuse (A):
16
-
El.Power1:
230 V 1 phase (Utility)
-
(Hz):
50/60