Area of use / certification
-
Onshore/offshore:
-
Standard:
Eexde IIA T3, Zone 2
Flow / Pressure / Volume
-
Q max (SCF/H):
180000
-
P-max (bar):
690
-
Diesel Tank Volume (ltr):
500
-
Diesel consumption (ltr/hr):
100
Pump / Engine
-
Triplex pump:
Hydrarig NP200 1,3" x 1,625"
-
Boost pump:
Weston 1,5" x 2,5" x 6"
-
Cold-ends:
Weston 1,625"
-
Vaporizer:
Hydrarig Pot type IPP 00001
-
Motor:
Detroit diesel 8V-92TA, 480 HP, max. 2100 revolutions, IIA T3 Zone II
-
Motor (serial no.):
8VF-083345
-
Filter LIN suction side:
Washable strainer
-
Fire /Gas central:
CEAG GHG 6645 002 II 2 (1)G EEx de [ia] IIC T6
230 V 50-60 Hz
-
Signal to platform at:
Alarm on general fault, fire and gas
-
Air/Diesel shut down at:
- Over racing of motor.
- High temperature on exhaust.
- High temperature on cooling liquid.
- Low oil pressure on motor.
- Low air pressure.
- Fire alarm.
- Gas alarm.
- Emergency shut-down.
- Emergency shut-down from control room.
- Overpressure nitrogen.
Power supply
-
Fuse (qty):
1
-
Fuse (A):
16
-
El.Power1:
230 V 1 phase (Utility)
-
(Hz):
50/60
Additional information
-
Equipment / Functions:
- Derated capacity : 180.000 SCF/H @ 550 Bar. / 150.000 SCF/H @ 690 Bar
- Fixed fire extinguiser PEFS Foam.
- Fire extinguisher 12kg.
- OPS connection.