Area of use / certification
-
Onshore/offshore:
-
Standard:
ATEX II3G Eex de [ia] IIC T3, Z-015, Zone II, Type G, 83dBa
Flow / Pressure / Volume
-
Q max (SCF/H):
180000
-
P-max (bar):
690
-
Diesel Tank Volume (ltr):
770
-
Diesel consumption (ltr/hr):
110
Pump / Engine
-
Triplex pump:
CS&P Cryogenics ICPE-200
-
Triplex pump Serial no.:
003667
-
Boost pump:
CS&P Cryogenics 1,5x2,5x6
-
Cold-ends:
1 5/8” ICPE-200
-
Vaporizer:
CS&P Pot Vaporizer 180K SCFH
-
Motor:
Deutz BF6 1015 MC 330 kW 442 HK
-
Motor (serial no.):
9165781
-
Filter LIN suction side:
1 ½” – 100 Mesh washable strainer
-
Fire /Gas central:
Trade Tech GHG 6645
-
Signal to platform at:
Fire and gas alarm
-
Air/Diesel shut down at:
- Over racing of motor.
- High temperature on exhaust.
- High temperature on cooling liquid.
- Low oil pressure on motor.
- Low air pressure.
- Fire alarm.
- Gas alarm.
- Emergency shut-down.
- Emergency shut-down from control room.
- Overpressure nitrogen.
Power supply
-
Fuse (qty):
1
-
Fuse (A):
16
-
El.Power1:
230 V 1 phase (Utility)
-
(Hz):
50/60
Additional information
-
Equipment / Functions:
- Fixed fire extinguiser PEFS Foam.
- Fire extinguisher 12kg.
- OPS connection.