Area of use / certification
Flow / Pressure / Volume
-
Q max (SCF/H):
180000
-
P-max (bar):
690
-
Diesel Tank Volume (ltr):
500
-
Diesel consumption (ltr/hr):
72
Pump / Engine
-
Triplex pump:
Hydrarig NP200 1,3" x 1,625"
-
Boost pump:
Hydrarig 1,5 x 2,5 x 6
-
Cold-ends:
Hydrarig 1,625"
-
Vaporizer:
Hydrarig Pot SN.9925
-
Motor:
John Deere 6135 SFM75, 558 HK, max 1800 rpm
IIA T3 Sone II ATEX
-
Motor (serial no.):
RG 6135G000 768
-
Filter LIN suction side:
Washable strainer
-
Fire /Gas central:
24V DC JCE EEx d IIB T6
-
Signal to platform at:
Fire alarm, gas alarm, fault on gas/fire detectors
-
Air/Diesel shut down at:
- Over racing of motor.
- High temperature on exhaust.
- High temperature on cooling liquid.
- Low oil pressure on motor.
- Low air pressure.
- Fire alarm.
- Shutdown and alarm at 10% LEL gas (CH4)
- Emergency shut-down.
- Emergency shut-down from control room.
- Overpressure nitrogen
Power supply
-
Fuse (qty):
1
-
Fuse (A):
16
-
El.Power1:
230 V 1 phase (Utility)
-
(Hz):
50/60
Additional information
-
Equipment / Functions:
- Fixed fire extinguiser PEFS Foam.
- Fire extinguisher 12kg.
- OPS connection.