Area of use / certification
Flow / Pressure / Volume
-
Q max (SCF/H):
180000
-
Q-max - Alternative 2 (SCF/H):
100000
-
P-max (bar):
690
-
P-max Alternative 2 (bar):
1034
-
Diesel Tank Volume (ltr):
500
-
Diesel consumption (ltr/hr):
120
Pump / Engine
-
Triplex pump:
CS&P Cryogenics ICPE-200
-
Boost pump:
CS&P Cryogenics 1,5 x 2, 5 x 6
-
Cold-ends:
CS&P 1,625" – 1,25"
-
Vaporizer:
CS&P Pot Vaporizer 180K SCFH 15000 PSI
-
Motor:
Caterpillar C-15 ATEX Petroleum, 540BHP@2000RPM
-
Motor (serial no.):
HAZ00804
-
Filter LIN suction side:
1 ½" – 100 mesh washable strainer
-
Signal to platform at:
Fire alert, Gas alert, fault at gas/fire detector
-
Air/Diesel shut down at:
- Overspeed of motor
- High exhaust temperature
- High coolant temperature
- Low oil pressure in motor
- Low air pressure
- Fire alert
- Gas alert
- Emergency stop
- Emergency stop from control room
- Low lubricate oil pressure pump
Additional information
-
Equipment / Functions:
Standard delivery is 10K (690 bar) / 3000 SCF/M. Possibilty to Convert to 15K (1034 bar) 1,25'' Cold End on request
- SafeGuard™ Novec 1230 fire extinguisher system,
- Fire extinguisher 12kg.
- OPS connections.
- The unit is certified by Notified Body (DNV) ) to drive without flame traps in the exhaust in dangerous areas (Zone 2).