Area of use / certification
-
Onshore/offshore:
-
Standard:
Zone 2, 2014/34/EU, ATEX Equipment Directive, 89dbA
2006/42/EC Machinery Directive
BS EN 1127-1:2019
BS EN 1834-1:2000 Reciprocated internal combustion engines
2006/42/EC Machinery Directive
2014/68/EU Pressure Equipment Direcrive
2014/30/EC EMC Directive
Flow / Pressure / Volume
-
Q max (SCF/H):
90000
-
P-max (bar):
690
Pump / Engine
-
Triplex pump:
Manufacturer: CS&P / Model no: ICP 100
-
Triplex pump Serial no.:
747-05166-00007
-
Boost pump:
Manufacturer: Cryogenic Industrial Supplies / Model no: CRP100 boost pump / Part no: CR0012
-
Cold-ends:
CS&P - 1.25" 10k (3 off)
-
Vaporizer:
Cryogenic Industrial Supplies - Part no: 90k-10k
-
Motor:
Volvo D7 Engine, Part no: D7C-B TA,
-
Motor (serial no.):
5312554581
-
Filter LIN suction side:
Washable strainer
-
Fire /Gas central:
Superseded with flame trap system
-
Air/Diesel shut down at:
- Engine overspeed 3400 rpm
- Low oil pressure 10 psi falling
- High exhaust temperature 198 degrees C
- High coolant temperature 100 degrees C
- Low hydraulic oil level
Emergency Stop
Additional information
-
Equipment / Functions:
Designed for use in Zone II - 3G areas
UNIT IS LOCATED IN UK:
Tel: 01224 725599 Fax: 01224 228349
IKM Testing UK Ltd, Peregrine Road, Westhill, AB32 6JL. www.IKM.com