Area of use / certification
-
Onshore/offshore:
Offshore
Flow / Pressure / Volume
-
Tank Volume (ltr):
7730
-
P-max (bar):
6
-
P-max Transport (bar):
2
Connections
-
Inlet connection:
ACME NI 150
-
Outlet connection:
ACME NI 150
Additional information
-
Equipment / Functions:
TANK SHALL NOT BE FILLED MORE THAN 95% (7344 ltr)
Double set of safety valves, transport valve, drip pan under valve armatures, manometer and level gauge.
To avoid condensation/icing, the tank must always be pressurised.
Inlet Connection LN2 behind.