PUMP FOR PIGGING / CHEMICAL CLEANING
Construction year
-
Built:
1998
-
Upgraded/rebuilt:
2022
Area of use / certification
-
Onshore/offshore:
-
Standard:
Eexde IIB T4 Zone 1
-
Power (Electrical/Diesel):
Flow / Pressure / Volume
-
Hz v Q-max measure:
60
-
Q-max (l/min):
1000
-
Hz v P-max measure:
60
-
P-max (bar):
9.1
Pump(s)
-
Pump1 (type):
Jet-pump type VRF 425
-
Pump1 (Cert. No.):
17005-17
Power supply
-
Fuse (qty):
1
-
Fuse (A):
63
-
El.Power1:
400 VD
-
(Hz):
50
-
(kW):
18,5
-
(A):
32
-
El.Power2:
400 VD
-
(Hz):
60
-
(kW):
18,5
-
(A):
32
-
El.Power3:
440-480 VD
-
(Hz):
60
-
(kW):
22,0
-
(A):
34,5-31,5
-
El.Power4:
690 VY
-
(Hz):
50
-
(kW):
19,0
-
(A):
18,5
-
El.Power5:
660–690
-
(Hz):
60
-
(kW):
18,5
-
(A):
19,4-18,6
-
Starter:
MES type 19-004
Snr 2000130-001
Presafe 19 ATEX 14431 X
II 2 G Ex db eb IIC T6 Gb
400-690v 50/ 60Hz
Additional information
-
Equipment / Functions:
Valves on ”connection out” to control flow/pressure, 1 ea valve in doc cabinet
Pump in acid-resistant material. Frame in carbon steel. Driving under P min. will cause that the motor protection will post.