Dimensions

  • Length(mm):
    1150
  • Width(mm):
    600
  • Height(mm):
    1450
  • Weight (kg):
    500
  • Lifting/ Transportation:
    Frame with forklift channels

Construction year

  • Built:
    1992
  • Upgraded/rebuilt:
    2022

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIC T4 Zone 1
  • Power (Electrical/Diesel):

    Electrical

Flow / Pressure / Volume

  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    1000
  • Hz v P-max measure:
    60
  • P-max (bar):
    9
  • Flowrate1:
    500 ltr/min @ 7,5 bar (50Hz)
  • Flowrate2:
    660 ltr/min @ 7 bar (50Hz)
  • Flowrate3:
    800 ltr/min @ 6 bar (50Hz)

Connections

  • Inlet connection:
    1 ea. 4" 150# RF flange
  • Outlet connection:
    2 ea. 2” Camlock Female/Male 2 ea. 1” Camlock Female/Male

Pump(s)

  • Pump1 (type):
    Ydra VRF 415-25
  • Pump1 (Cert. No.):
    115749

Motor / Engine(s)

  • Motor1 (type):
    Bartec Varnost 4KTC 160L-2 II2G EEx de IIC T4 (Cert. No: PTB 99 ATEX 1138)
  • Motor1 (Cert. No.):
    2650

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    18,5
  • (A):
    34,7
  • El.Power2:
    660-720 VY
  • (Hz):
    50
  • (kW):
    18,5
  • (A):
    20,0
  • El.Power3:
    380-415 VD
  • (Hz):
    60
  • (kW):
    18,5
  • (A):
    34,6
  • El.Power4:
    660-690 VY
  • (Hz):
    60
  • (kW):
    18,5
  • (A):
    20,0
  • El.Power5:
    440-480 VD
  • (Hz):
    60
  • (kW):
    21,3
  • (A):
    35,2
  • Starter:

    Technor TNCD 282827 Ser. Nr: 962518

    Eexde IIC T5 IP-54

    400-690 V 50-60 Hz Max. load 37 A

Additional information

  • Equipment / Functions:

    Valves on "connection outlet" to control flow/pressure.

    Pump in acid-resistant material. Frame in 316. Driving under P min. (5,8 bar) will cause that the motor protection will post.