PUMP FOR PIGGING / CHEMICAL CLEANING
Area of use / certification
Flow / Pressure / Volume
-
Hz v Q-max measure:
N/A (Diesel)
-
Q-max (l/min):
6200
-
Hz v P-max measure:
N/A (Diesel)
-
P-max (bar):
28
-
Flowrate1:
1250 ltr/min @ 28 bar
-
Flowrate2:
4250 ltr/min @ 24 bar
-
Flowrate3:
6200 ltr/min @ 17 bar
-
Diesel Tank Volume (ltr):
500
-
Diesel consumption (ltr/hr):
85
Connections
-
Inlet connection:
8” 150# RF
-
Outlet connection:
4” 300# RF
Power supply
-
Fuse (qty):
1
-
Fuse (A):
16
-
El.Power1:
230V
-
(Hz):
50/60
-
(A):
10-16
-
Control Panel:
Ceag GHG 6645 (Ser. No: J1972DS) Eexde IIC T6
230 V, 1 phase, 2,5 A, 50/60 Hz
Additional information
-
Equipment / Functions:
Manometer on pressure side and pressure/vacuum indicator on suction side.
Fixed fire extinguiser PEFS Foam.
Fire extinguisher 12kg.
Signal to platform if:
- Fire and gas alarm.
Air/Diesel supply closes if
- To high r.p.m on motor.
- High exhaust temperature.
- High antifreeze temperature.
- Low oil pressure on motor.
- Low air pressure.
- 20 Lel Gas alarm.
- Fire alarm
- Emergency stop.
- Emergency stop from control room.