Dimensions

  • Length(mm):
    2700
  • Width(mm):
    1200
  • Height(mm):
    1600
  • Weight (kg):
    3000
  • Lifting/ Transportation:
    Frame with forklift pockets and lifting. DNV 2.7-1 Ref. cert. Frame: 2139822 / PP-108

Construction year

  • Built:
    2014

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Norsok Z-015, Zone 1
  • Power (Electrical/Diesel):

    Electrical

Flow / Pressure / Volume

  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    2600
  • Hz v P-max measure:
    60
  • P-max (bar):
    30
  • Flowrate1:
    766 ltr/min @ 29,5 bar (60Hz)
  • Flowrate2:
    2000 ltr/min @ 25,03 bar (60Hz)
  • Flowrate3:
    2608 ltr/min @ 20,25 bar (60Hz)

Connections

  • Inlet connection:
    6” 150# RF, Alternative DN125 CL300
  • Outlet connection:
    4” 300# RF, Alternative DN100 CL600

Pump(s)

  • Pump1 (type):
    KSB Multitec D 100/ 3-7.1 30.67 II 2G c TX
  • Pump1 (Cert. No.):
    9972611883/000100/01

Motor / Engine(s)

  • Motor1 (type):
    ATB BD 315L1-2 A II 2G Ex de IIB T4 Cert No: PTB 09 ATEX 1011 X
  • Motor1 (Cert. No.):
    541952002

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    300
  • El.Power1:
    400 VD
  • (Hz):
    50
  • (kW):
    160
  • (A):
    270
  • El.Power2:
    690 VY
  • (Hz):
    50
  • (kW):
    160
  • (A):
    155
  • El.Power3:
    400 VD
  • (Hz):
    60
  • (kW):
    160
  • (A):
    270
  • El.Power4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    176
  • (A):
    270-245
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    160
  • (A):
    163-156
  • Control Panel:

    CEAG GHG 64 size-9 / AK5-1 (Ser. No: 14-002)

    Ex d e mb [ia Ga] IIB T6 (Cert. No: PTB 08 ATEX 1042U / PTB 02 ATEX 1021U)

    400-440-480-660-690 50/60 Hz (NEMKO Nr. 14 ATEX 2053)

Additional information

  • Equipment / Functions:

    EL. POWER:

    Cable size : Main power P-001: 4G120 mm²

    Rec. Backup fuse : 400-480 V: 300 A “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)

    660-690 V: 180 A “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)

    - Pressure gauge on the inlet.

    - Gate valve on outlet

    - Pressure gauge before and after Gate valve on outlet

    - Valve for venting the pump housing.

    - Valve for frost protection in pump.

    - Monitoring phase sequence, Feed wate