PUMP FOR PIGGING / CHEMICAL CLEANING
Area of use / certification
-
Onshore/offshore:
-
Standard:
Norsok Z-015, Zone 1
-
Power (Electrical/Diesel):
Flow / Pressure / Volume
-
Hz v Q-max measure:
60
-
Q-max (l/min):
2600
-
Hz v P-max measure:
60
-
P-max (bar):
30
-
Flowrate1:
766 ltr/min @ 29,5 bar (60Hz)
-
Flowrate2:
2000 ltr/min @ 25,03 bar (60Hz)
-
Flowrate3:
2608 ltr/min @ 20,25 bar (60Hz)
Connections
-
Inlet connection:
6” 150# RF, Alternative DN125 CL300
-
Outlet connection:
4” 300# RF, Alternative DN100 CL600
Power supply
-
Fuse (qty):
1
-
Fuse (A):
300
-
El.Power1:
D 380-415
-
(Hz):
50
-
(kW):
160
-
(A):
266,0
-
El.Power2:
Y 660-720
-
(Hz):
50
-
(kW):
160
-
(A):
153,5
-
El.Power3:
D 380-415
-
(Hz):
60
-
(kW):
160
-
(A):
274,0
-
El.Power4:
Y 660-690
-
(Hz):
60
-
(kW):
160
-
(A):
158,0
-
El.Power5:
D 440-480
-
(Hz):
60
-
(kW):
176
-
(A):
258,0
-
Control Panel:
Control cabinet (Ser. No: 76010-EC-002)
II 2 G EEx de IIB T4
400-440-480-660-690 50/60 Hz (NEMKO No. 15 ATEX 2121)
Additional information
-
Equipment / Functions:
EL. POWER:
Cable size : Main power 1- P-001 4 G 120 mm²
Rec. Backup fuse :
400-480 V: 300 A “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)
660-690 V: 180 A “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)
- Pressure gauge on the inlet.
- Gate valve on outlet
- Pressure gauge before and after Gate valve on outlet
- Valve for venting the pump housing.
- Valve for frost protection in pump.
- Monitoring phase sequence.
- Level guard