Dimensions

  • Length(mm):
    5875
  • Width(mm):
    2438
  • Height(mm):
    3035
  • Weight (kg):
    20000
  • Lifting/ Transportation:
    20’ Offshore ISO container with forklift channels and lifting slings in accordance to DNV 2.7-1 . Can be stacked in height with use of ISO locks Ref.cert. / Ser. no. frame : PP-118A / HHP-20/1

Construction year

  • Built:
    2010

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Offshore Zone 2, 83dBA, Norsok Z-015 SOLAS 74 Ch.11-2, ATEX II 3G IIA T3
  • Power (Electrical/Diesel):

    Diesel

Flow / Pressure / Volume

  • Hz v Q-max measure:
    N/A (Diesel)
  • Hz v P-max measure:
    N/A (Diesel)
  • Diesel Tank Volume (ltr):
    1200
  • Diesel consumption (ltr/hr):
    220

Pump(s)

  • Pump1 (type):
    MUST BE CONNECTED TO SEPERATE PUMP UNIT (PP-118B)

Motor / Engine(s)

  • Motor1 (type):
    Caterpillar C-32 1450BHP (900HHP)
  • Motor1 (Cert. No.):
    RNY 00421

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    16
  • El.Power1:
    110-230V
  • (Hz):
    50/60
  • (A):
    10-16
  • Control Panel:
    Ceag GHG 6645 (Ser. No: J1972DS) Eexde IIC T6 230 V, 1 phase, 2,5 A, 50/60 Hz

Additional information

  • Equipment / Functions:

    MUST BE CONNECTED TO SEPERATE PUMP UNIT (PP-118B), (see separate datasheets for technical information)

    - Diesel tank is located at pump unit, Diesel level must be limited to 600 liters for offshore use.

    - Signal to platform if : Fire and gas alarm

    - Novec 1230 Fire extinguishing system

    - Fire extinguisher 12kg.

    - Unit is certified by Notified Body (DNV) to run without flame traps in the exhaust in hazardous area (Zone 2).

    - Two-piece unit, where the engine and pump has to be connected via a drive shaft, hydraulic and diesel hoses.

    MOTOR SHUT DOWN IF:

    - To high r.p.m on motor.

    - High exhaust temperature.

    - Emergency stop from control room

    - High coolant temperature.

    - Emergency stop.

    - Low level coolant

    - Fire alarm

    - Low oil pressure.

    - 10% Lel Gas alarm.