PP-118B
PUMP FOR PIGGING / CHEMICAL CLEANING
PUMP FOR PIGGING / CHEMICAL CLEANING
Offshore
Diesel
MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-118A), (see separate datasheets for technical information)
Two-piece unit, where the engine and pump has to be connected via a drive shaft, hydraulic and diesel hoses.
Diesel level must be limited to 600 liters for offshore use.
Feed water pressure: Minimum 3,5 bar at full flow on triplex pump.
LIMITATIONS
80% load is 960 HHP@ 2100 rpm, can be used for 50% of the duty cycle or 6 out of every 12 hours.
70% load is 840 HHP @ 2100 rpm. Operation below this can be used cyclic continuous.
100% load is 1150 HP @ 2100 rpm, Can be used for maximum one hour. The following hour has to be below
70% (840 HHP @ 2100 rpm)
If the speed is lowered to 1800 rpm, the full load is lowered to 1040 HHP.
80% load is 830 HHP@ 1800 rpm.
70% load is 730 HHP @ 1800 rpm.
If these limits are exceeded there will be limited warrant.
For further information please contact Maintenance Diesel Department.