Dimensions

  • Length(mm):
    2200
  • Width(mm):
    1400
  • Height(mm):
    2000
  • Weight (kg):
    2500
  • Lifting/ Transportation:
    Frame with lifting devices and forklift channels. DNV 2.7-1 Ref. Cert. / Ser. no. frame 11625 / PP-16

Construction year

  • Built:
    1994
  • Upgraded/rebuilt:
    2022

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIB T3, Zone 1 , Norsok Z-015
  • Power (Electrical/Diesel):

    Electrical

Flow / Pressure / Volume

  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    2839
  • Hz v P-max measure:
    60
  • P-max (bar):
    6,4
  • Flowrate1:
    2000L @ 5,5Bar @ 60Hz
  • Flowrate2:
    1930L @ 3,0Bar @ 50Hz
  • Flowrate3:
    770L @ 4,5Bar @ 50Hz

Connections

  • Inlet connection:
    1 ea. 4" 150# RF flange
  • Outlet connection:
    1 ea. 4” 150# RF flange

Pump(s)

  • Pump1 (type):
    Halco, Mission Supreme 2500 Pump 4x3x13 (7" Impeller)
  • Pump1 (Cert. No.):
    S163296

Motor / Engine(s)

  • Motor1 (type):

    Brook Crompton W-EF250

    II2G EEx de IIB T3 (Tamb*)

    BAS 02 ATEX 2115 X

  • Motor1 (Cert. No.):
    0302595/001/001 02-00612

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    125
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    55
  • (A):
    98-90
  • El.Power2:
    440-480 VD
  • (Hz):
    60
  • (kW):
    63
  • (A):
    97-89
  • El.Power3:
    690 VY
  • (Hz):
    60
  • Starter:

    Ceag GHG 665 5002 R0915

    Eexde IIC T4 (T6) Cert. No: PTB98 ATEX 1054U

    400-440-480-690 V 50-60Hz

Additional information

  • Equipment / Functions:

    -Pump in cast iron material

    -Gate Valve Outlet

    -Alle flow/trykk målinger er med SG-1 (Vann)