PP-24A
PUMP FOR PIGGING / CHEMICAL CLEANING
PUMP FOR PIGGING / CHEMICAL CLEANING
Offshore
Diesel
MUST BE CONNECTED TO SEPERATE PUMP UNIT (PP-24B Triplex or PP-24C Centrifugal), (see separate datasheets for technical information)
Two-piece unit, where the engine and pump has to be connected via a drive shaft, hydraulic and diesel hoses (Diesel tank is located at pump unit).
The unit is driven at a fixed RPM. Pressure/flow can be regulated by using a 5 step gearbox.
Fixed fire extinguiser Novec.
Fire extinguisher 12kg.
Signal to platform if : Fire and gas alarm
MOTOR SHUT DOWN IF:
- To high r.p.m on motor.
- Protective guard on pump.
- High exhaust temperature.
- Emergency stop from control room
- High coolant temperature.
- Emergency stop.
- Low oil pressure.
- Fire alarm
- Low air pressure.
- 10% Lel Gas alarm.