Dimensions

  • Length(mm):
    2991
  • Width(mm):
    2438
  • Height(mm):
    2896
  • Weight (kg):
    13000
  • Lifting/ Transportation:
    10’ Offshore ISO container with forklift pockets and lifting slings. DNV 2.7-1 Can be stacked in height with use of ISO locks.

Construction year

  • Built:
    2013
  • Upgraded/rebuilt:
    2018

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Offshore, Zone II, Norsok Z-015, ATEX II 3G IIA T3
  • Power (Electrical/Diesel):

    Diesel

Flow / Pressure / Volume

  • Hz v Q-max measure:
    N/A (Diesel)
  • Q-max (l/min):
    3600
  • Hz v P-max measure:
    N/A (Diesel)
  • P-max (bar):
    525
  • Flowrate1:
    3602 ltr/min @ 113 bar (6" Plunger@7. gear, 2100 RPM)
  • Flowrate2:
    2035 ltr/min @ 201 bar (6" Plunger@4. gear, 2100 RPM)
  • Flowrate3:
    961 ltr/min @ 425bar (6" Plunger@1. gear, 2100 RPM)
  • Diesel Tank Volume (ltr):
    1200
  • Diesel consumption (ltr/hr):
    280

Connections

  • Inlet connection:
    6” 150 Ansi via integrated feed pump or external feeder minimum 3.5 bar at full flow on triplex pump
  • Outlet connection:
    2 ea. 3" Fig 1502 Female.

Pump(s)

  • Pump1 (type):
    Gardner Denver GD-2250 Triplex pump . Standard Plunger 6", other sizes on request.

Motor / Engine(s)

  • Motor1 (type):
    MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-74A)

Power supply

  • (A):
    10-16

Additional information

  • Equipment / Functions:

    MUST BE CONNECTED TO SEPERATE MOTOR UNIT (PP-74A), (see separate datasheets for technical information)

    Two-piece unit, where the engine and pump has to be connected via a drive shaft, hydraulic and diesel hoses (Diesel tank is located at pump unit).

    Diesel level must be limited to 600 liters for offshore use.

    Hydraulically integrated feed pump.

    LIMITATIONS:

    - 80% load is 960 HHP@ 2100 rpm, can be used for 50% of the duty cycle or 6 out of every 12 hours.

    - 70% load is 840 HHP @ 2100 rpm. Operation below this can be used cyclic continuous.

    - 100% load is 1150 HHP @ 2100 rpm, Can be used for maximum one hour. The following hour has to be below

    - 70% (840 HHP @ 2100 rpm)

    If the speed is lowered to 1800 rpm, the full load is lowered to 1040 HHP.

    - 80% load is 830 HHP@ 1800 rpm.

    - 70% load is 730 HHP @ 1800 rpm.

    - If these limits are exceeded there will be limited warrant.

    For further information please contact Maintenance Diesel Department.