Dimensions

  • Length(mm):
    1300
  • Width(mm):
    800
  • Height(mm):
    1390
  • Weight (kg):
    330
  • Lifting/ Transportation:
    Frame with forklift channels

Construction year

  • Built:
    2000

Area of use / certification

  • Onshore/offshore:

    Onshore

Type

  • Fabricator:
    Pall
  • Model:
    HNP 021
  • Serial no.:
    HNPE 524

Flow / Pressure / Volume

  • Q-max (l/min):
    20
  • P-max (bar):
    7
  • Min. viscosity (cst):
    10
  • Max. Viscosity (cst):
    700
  • Max temp. (GrC):
    70

Connections

  • Inlet connection:
    1 ea. 1" BSP
  • Outlet connection:
    1 ea. 1" BSP

Pump(s)

  • Pump1 (type):
    Rietschle VCB-20

Power supply

  • Power (Electrical/Air):

    Electrical

  • Fuse (qty):
    1
  • Fuse (A):
    16
  • El.Power1:
    230 V, 1 phase
  • (Hz):
    50/60

Filter

  • Inlet Filter:

    Filter in: 1 ea. Washable strainer

    Coalescer filter element: 1 ea. Pall HS 74499

    Oil separator filter (Primary): 1 ea. Pall HS 75390

    Oil separator filter (Secondary): 1 ea. Washable filter

  • Outlet Filter:
    Filter element out: 1 ea. Pall HC 9100 FKS 8H Ventilating filter on tank : 1 ea. Pall HC 0293 SEE5

Additional information

  • Equipment / Functions:

    Oil Fire point : Min. 93ºC

    To dry up the oil, the working temperature ought to be between 40-60ºC to achieve the best efficiency.

    Example: at 25ºC the dry up is approx. 6 ltr/24 hours, at 60ºC the dry up is approx. 40 ltr/24 hours.