Dimensions

  • Length(mm):
    3700
  • Width(mm):
    2450
  • Height(mm):
    3035
  • Weight (kg):
    8500
  • Lifting/ Transportation:
    12' Offshore container with forklift channels and lifting slings. DNV 2.7-1
  • Certificate(s) / Serial No::
    42391

Construction year

  • Built:
    2004

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Norsok Z-015, CE, Unclassified area, (83 dBa)

Flow / Pressure / Volume

  • Boiler:
    Clayton E-185 (Ser. No: B-6973)
  • Spark Arrestor:

    DNV certified. (Ref. cert./Ser. no. : SU-30b / GF-01)

    Dimension : L 2820mm W 1000mm H 1570mm. Weight : 560 kg

    Lifting/Transport : 2-leg chain sling

  • Maximum Effect (kW):
    1850
  • Max. steam production (kg/hr):
    2900
  • P-max (bar):
    10
  • P-max (PSI):
    145
  • Max Steam temperature (Gr.C):
    184
  • Feed water tank volume (ltr):
    1130
  • Diesel Tank Volume (ltr):
    670
  • Diesel consumption (ltr/hr):
    210

Connections

  • Inlet connection:
    1" offshore claw coupling
  • Outlet connection:
    2” Steamcoupling Boss Spud (New type)

Filter

  • Inlet filter house (type):
    Feedwater inlet: HECO 899014001 Diesel inlet: RACOR 500 FG
  • Inlet filter element (type):
    Feedwater inlet: PX 2010 Diesel inlet: PF-598-30

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    400-480 V (main)
  • (Hz):
    50/60
  • (A):
    63 “slow”
  • El.Power2:
    690 V (main)
  • (Hz):
    50/60
  • El.Power3:
    230 V (Utility)
  • (Hz):
    50/60

Additional information

  • Equipment / Functions:

    High fire steam production : 2900 kg/hour @ 7,5 bar

    Low fire steam production : 1450 kg/hour @ 10 bar

    - The water consumption at full effect is 20% higher than the steam production.

    Sprinkler system : Swordsman foam system.

    Fire, gas central :

    Ceag EEx de IIC T5 – T6¹ Ser. no. 40202-1

    Ignition source connection and pressure relief steam if:

    - 10% gas alarm (Detector mounted near air inlet).

    - Fire alarm (Heat detector).

    - Emergency shut-down on the outside of the container and the interior of the container.

    - Emergency shut-down from control room.

    Other safety functions :

    - Flame detector on burner.

    - Ring thermostat on coil.

    - Level monitor in feed water tank.

    - Max. surface temperature is 200ºC.

    - Max. exhaust temperature is 300ºC.