Dimensions

  • Length(mm):
    6058
  • Width(mm):
    2438
  • Height(mm):
    2850
  • Weight (kg):
    15100
  • Lifting/ Transportation:
    20' Offshore container with forklift channels and lifting slings. DNV 2.7-1
  • Certificate(s) / Serial No::
    SW 20-117 / 2007023

Construction year

  • Built:
    2007

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Z-015 (type):
    U05
  • Standard:
    Norsok Z-015, Zone 2, (80 dBa)

Flow / Pressure / Volume

  • Boiler:
    PH 27 12 bar (Ser. nr. 19788)
  • Spark Arrestor:

    SPARK ARRESTOR:

    DNV certified. (Ref. cert./Ser. no. : SU-44b)

    Dimension : L 1560mm W 600mm H 840mm. Weight : 560 kg

    Lifting/Transport : Lifting lugs connected without lifting sling

    FAN BOX:

    Dimension : L 1380 mm W 1400 mm H 820 mm. Weight : 200 KG

    Lifting/Transport : Non approved lifting

    Ref. cert./Ser. no. : SU-44c

  • Maximum Effect (kW):
    1800
  • Max. steam production (kg/hr):
    2700
  • P-max (bar):
    12
  • P-max (PSI):
    175
  • Max Steam temperature (Gr.C):
    193
  • Diesel Tank Volume (ltr):
    800
  • Diesel consumption (ltr/hr):
    300

Connections

  • Inlet connection:

    Water: 1” Offshore clawcoupling (connected to 1 ¼” 150# RF)

    Diesel: 1” Camlock

    Air: 1” Offshore claw coupling

  • Outlet connection:

    Steam: 2” Steam coupling Boss Spud

    Condensate: 1” 150# RF

    Drain heater 1" camlock

    Depressurizing steam: 2” Steam coupling Boss Spud

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    400-690 V (main)
  • (Hz):
    50/60
  • (A):
    63 “slow”
  • El.Power2:
    230 V (Utility)
  • (Hz):
    50/60

Additional information

  • Equipment / Functions:

    Instrument air supply: 500 ltr/h, 4-6 bar

    Ignition source connection and pressure relief steam if:

    - Fire alarm

    - Gas alarm.

    - Emergency shut-down on the outside of the container

    - Emergency shut-down on motor starter cabinet

    - Loss of overpressure

    - Emergency shut-down from control room

    Other safety functions :

    - Flame detector on burner.

    - Feed water guard

    - Safety valve

    - Pressure guard / pressure controller

    - Steam thermostat