Dimensions

  • Length(mm):
    4267
  • Width(mm):
    2438
  • Height(mm):
    3000
  • Weight (kg):
    10500
  • Lifting/ Transportation:
    12" Offshore container with forklift channels and lifting slings. DNV 2.7-1

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Z-015 (type):

    U05

  • Standard:
    Norsok Z-015, CE, Unclassified area, (83 dB)

Technical information

  • Boiler:
    Clayton EO-204-2 Ser.no.:B8741
  • Spark Arrestor:
    DNV certified. (Ref. cert/Ser. no. : SU-92B)
  • Maximum Effect (kW):
    1964
  • Max. steam production (kg/hr):
    3131
  • P-max (bar):
    13
  • P-max (PSI):
    188
  • Max Steam temperature (Gr.C):
    195
  • Feed water tank volume (ltr):
    1800
  • Diesel Tank Volume (ltr):
    600
  • Diesel consumption (ltr/hr):
    211

Connections

  • Inlet connection:

    Water: 1" Offshore claw coupling

    Water spark arrestor: 1" Offshore claw coupling

    Condensate: 2" Camlock female

    Diesel: 1" Camlock female

  • Outlet connection:

    Steam: 2" Boss Dixon male (mounted in 3" 150# RF)

    Drain water tank: 2" Camlock female

    Steam drain: 1" Boss Dixon male

    Water spark arrestor 1" Offshore claw coupling

Filter

  • Inlet filter house (type):
    Diesel: 1002MAM10 Water: HECO 899014001
  • Inlet filter element (type):
    Water: PX 2010 Diesel: 2020V30
  • Outlet filter house (type):
    Diesel: 1002MAM10
  • Outlet filter element (type):
    Diesel: 2020V30

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    400-480 V
  • (Hz):
    50/60
  • El.Power2:
    660-690 V
  • (Hz):
    50/60
  • El.Power3:
    230 V
  • (Hz):
    50/60

Additional information

  • Equipment / Functions:

    The water consumption at full effect is 20% higher then the steam production.

    Water consumption unit: 3935 l/h. Spark arrestor: 1140 l/h.

    Unit is automodulating between 25 and 100% load.

    Sprinkler system: Inergen

    Fire and gas central:

    STAHL 8264/5224 KEMA 01 ATEX 2145X

    Ex II 2 G Ex db eb IIB T4 Gb

    Serie nr: 227790-01

    Ignition source connection and pressure relief steam if:

    -Gas alarm (detector mounted at air inlet).

    -Fire alarm.

    -Emergency shutdown inside and outside of the container.

    -Emergency shutdown from control room.

    -Error message from fire/gas central.

    Other safety functions:

    -Flame detector on burner.

    -PT100 element on coil.

    -Level monitor in feed water tank.

    -Max surface temperature is 200°C.

    -Max exhaust temperature is 300°C.