Dimensions

  • Length(mm):
    5120
  • Width(mm):
    2400
  • Height(mm):
    3430
  • Weight - Tara (kg):
    9800
  • Weight - Payload (kg):
    2200
  • Weight - Gross (kg):
    12000
  • Lifting/ Transportation:
    DNV 2.7-1:1995 Lifting Frame ATEX II 3G Ex h IIA T4 Gc (Zone 2)
  • Certificate(s) / Serial No::
    52112

Construction year

  • Upgraded/rebuilt:
    2021

Area of use / certification

  • Onshore/offshore:

    Offshore

Flow / Pressure / Volume

  • Tank Volume (ltr):
    17500

Additional information

  • Equipment / Functions:

    GENERAL

    Twin 110 BBL (2 x 55BBL Tanks) Hydraulic Driven Batch Mixer suitable for operation in a Zone 2 hazardous environment when operated with a suitably rated and certified HPU. Unit c/w hydraulic driven agitation paddles installed within each tank, jet mixing and recirculating lines, pneumatically actuated butterfly valves installed in suction and drain lines, intended for mixing of cement slurries with a max fluid density of 1.98 SG (16.5 PPG) & fluid blending operations.

    HYDRAULICS

    • 210 bar max supply pressure

    • 100 lpm max flow rate required to operate both agitators

    • Agitator(s) speed 0 - 85 rpm(Recommended)

    • Bulkhead c/w ISO ‘A’ type quick connects installed i.e.: 1” supply, 1,¼” return, ¼” drainand crowsfoot air connection

    • Single HPU supply flows through a 50/50 flow divider allowing for even split of hydraulic flow to each agitation control.

    • Variable speed control of agitation via panel mounted pressure compensated flow regulated ‘bypass’ style valves.

    • 1 x 1” QD female Hydraulic supply

    • 1 x 1”1/4 QD male Hydraulic return

    • 1 x ¼” QD female Hydraulic Drain

    • 1 x ¼ QD male ESD Connection

    • 1 x 1” cross foot air supply

    AUXILLARY SUPPLIES: HYD. POWER PACK & AIR.

    Appropriate hydraulic power pack to be utilised to supply required hydraulic oil supply ensuring suitably rated and certified to meet with batch mixer hazardous area Zone 2 rating. Clean and dry instrument air supply required max pressure 10 bar.

    Appropriate hydraulic power pack to be utilised to supply required hydraulic oil supply ensuring suitably rated and certified to meet with batch mixer hazardous area Zone 2 rating. Clean and dry instrument air supply required max pressure 10 bar.

    • 1 x 4”fig 206 thread suction line

    • 1 x 4”fig 206 thread discharge line

    LOCAL CONTROL PANEL

    Engraved Stainless Steel Control panel located on the unit giving central control for agitation and suction / drain valves and visual display of agitation hydraulic pressure etc.

    SAFETY

    • Full access stairway and barrier / handrail system to enable safe operation and maintenance at height.

    • Sample points situated at an ergonomic position for operator comfort.

    • Butterfly Valves pneumatically operated for ease of operation where access is limited withmanual valves positioned where access is available.

    • Hose connections located at ground level for manual handling ease when rigging up.