Dimensions

  • Length(mm):
    1900
  • Width(mm):
    2000
  • Height(mm):
    1800
  • Weight (kg):
    2200
  • Lifting/ Transportation:
    Frame with forklift channels and lifting slings. Slings and shackles in acc. to DNV 2.7-1. Frame in acc. to Machine directives (cert. frame : BO-2)

Construction year

  • Built:
    1992
  • Upgraded/rebuilt:
    2008

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIC T4 Zone 1

Flow / Pressure / Volume

  • Tank Volume (ltr):
    1200
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    420
  • Hz v P-max measure:
    50
  • P-max (bar):
    350
  • Flowrate1:
    35 l/min @ 350 bar (50 Hz)
  • Flowrate2:
    50 l/min @ 250 bar (50 Hz)
  • Flowrate3:
    185 l/min @ 50 bar (50 Hz)
  • Min. viscosity (cst):
    10
  • Max. Viscosity (cst):
    75
  • Start Viscosity (cst):
    600

Connections

  • Inlet connection:
    2 ea 1" BSP
  • Outlet connection:
    2 ea 1" BSP

Pump(s)

  • Pump1 (type):
    Volvo V30, B121 128 RK-H
  • Pump1 (Cert. No.):
    481291001
  • Pump2 (type):
    Volvo V30, B121 128 RK-H
  • Pump2 (Cert. No.):
    481291002

Motor / Engine(s)

  • Motor1 (type):
    ATB BD 200L-4
  • Motor2 (type):
    ATB BD 200L-4

Power supply

  • Fuse (qty):
    2
  • Fuse (A):
    63
  • El.Power1:
    400 VD
  • (Hz):
    50
  • (kW):
    30
  • (A):
    53
  • El.Power2:
    400 VD
  • (Hz):
    60
  • (kW):
    30
  • (A):
    52
  • El.Power3:
    400-480 VD
  • (Hz):
    60
  • (kW):
    34,5
  • (A):
    55
  • El.Power4:
    690 VY
  • (Hz):
    50
  • (kW):
    30
  • (A):
    31
  • El.Power5:
    660-690 VD
  • (Hz):
    60
  • (kW):
    30
  • (A):
    32
  • Starter:

    CEAG GHG 6655 (Ser. No: J07 1097 /D/M).

    II2G EEx dem IIC T6 (Cert. No: PTB 98 ATEX 1054U).

    400-690V 50-60Hz 63A (Nemko No: 08 ATEX 2047)

Filter

  • Filter outlet (qty):
    2
  • Filterhouse (type):
    Parker 34P-2
  • Filterelement (type):
    Parker GO 1099/D731G03A
  • Filter inlet (qty):
    2
  • Filterhouse (type):
    Parker 34P-2
  • Filterelement (type):
    Parker GO 1099/D731G03A

Additional information

  • Equipment / Functions:

    Q-MAX IS TOTAL FLOW FOR BOTH PUMPS (PUMP 1: 210 ltr/min - PUMP 2: 210 ltr/min).

    Outlet for samples, flow indicator, heat exchanger, manual control of flow and level monitor in tank.