Construction year
-
Built:
1995
-
Upgraded/rebuilt:
2012
Area of use / certification
-
Onshore/offshore:
-
Standard:
Eexde IIC T4 Zone 1
Flow / Pressure / Volume
-
Tank Volume (ltr):
600
-
Hz v Q-max measure:
60
-
Q-max (l/min):
340
-
Hz v P-max measure:
50
-
P-max (bar):
350
-
Flowrate1:
15 l/min @ 320 bar (50 Hz)
-
Flowrate2:
40 l/min @ 200 bar (50 Hz)
-
Flowrate3:
140 l/min @ 50 bar (50 Hz)
-
Min. viscosity (cst):
10
-
Max. Viscosity (cst):
68
-
Start Viscosity (cst):
1000
Connections
-
Inlet connection:
2 ea 1" BSP
-
Outlet connection:
2 ea 1" BSP
Pump(s)
-
Pump1 (type):
PV092R1K1T1NKLCX5889
-
Pump1 (Cert. No.):
33281945-001
-
Pump2 (type):
PV092R1K1T1NKLCX5889
-
Pump2 (Cert. No.):
33281945-002
Power supply
-
Fuse (qty):
1
-
Fuse (A):
125
-
El.Power1:
380-415 VD
-
(Hz):
50
-
(kW):
18,5
-
(A):
35,3
-
El.Power2:
660-720 VY
-
(Hz):
50
-
(kW):
20,4
-
(A):
20,4
-
El.Power3:
400 VD
-
(Hz):
60
-
(kW):
18,5
-
(A):
35,0
-
El.Power4:
400-480 VD
-
(Hz):
60
-
(kW):
21,2
-
(A):
35,2
-
El.Power5:
660-690 VY
-
(Hz):
60
-
(kW):
18,5
-
(A):
21,0
-
Starter:
Stahl Eexde IIC T6 (Ser. No: 67104).
400-440-480 / 660-690V Max. load: 75 A
Additional information
-
Equipment / Functions:
Q-MAX IS TOTAL FLOW FOR BOTH PUMPS (PUMP 1: 170 ltr/min - PUMP 2: 170 ltr/min).
Flow indicator, outlet for samples, 2 ea.Oil coolers, thermometer