Dimensions

  • Length(mm):
    1100
  • Width(mm):
    1800
  • Height(mm):
    1900
  • Weight (kg):
    1300
  • Lifting/ Transportation:
    Frame with forklift channels and lifting slings, lifting according to machinery directive 6020 (onshore lifting only)

Construction year

  • Built:
    1991

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde II T3 Zone 1. In acc. to Norsok Z-015

Flow / Pressure / Volume

  • Tank Volume (ltr):
    650
  • Hz v Q-max measure:
    50
  • Q-max (l/min):
    210
  • P-max (bar):
    210
  • Flowrate1:
    50 ltr/min @ 210 bar
  • Flowrate2:
    70 ltr/min @ 150 bar
  • Flowrate3:
    115 ltr/min @ 50 bar
  • Min. viscosity (cst):
    15
  • Max. Viscosity (cst):
    162
  • Start Viscosity (cst):
    1618

Connections

  • Inlet connection:
    1 ea 1" BSP
  • Outlet connection:
    1 ea 1" BSP

Pump(s)

  • Pump1 (type):
    Denison PVT 29 with effect regulator and remote control
  • Pump1 (Cert. No.):
    01008921 Cod: 02209990-0

Motor / Engine(s)

  • Motor1 (type):
    Bartec Varnost (4KTC 200 L-4) EEx de IIC T4 Cert. No: PTB 05 ATEX 1099
  • Motor1 (Cert. No.):
    200718223

Power supply

  • Fuse (A):
    80
  • El.Power1:
    380-415 D
  • (Hz):
    50
  • (kW):
    30
  • (A):
    53
  • El.Power2:
    660-720 Y
  • (Hz):
    50
  • (kW):
    30
  • (A):
    31
  • El.Power3:
    380-415 D
  • (Hz):
    60
  • (kW):
    30
  • (A):
    54,6
  • El.Power4:
    660-690 Y
  • (Hz):
    60
  • (kW):
    30
  • (A):
    31,5
  • El.Power5:
    440-480 D
  • (Hz):
    60
  • (kW):
    34.5
  • (A):
    53,3
  • Starter:

    Stahl 8264/222-3110-S,

    EEx de IIBT6,

    400-690 V 50-60 Hz

Filter

  • Filter outlet (qty):
    1
  • Filterhouse (type):
    Finnfilter FF 7008 F003 BK 35 GL24
  • Filterelement (type):
    Finnfilter FC 7008 F003 BS/P169433/D143G03A
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    Finnfilter FF 1302 F003 BK
  • Filterelement (type):
    Finnfilter FC 1302 F003 BS/R432G03

Additional information

  • Equipment / Functions:

    Flow indicator, heat exchanger and outlet for samples, level sensor.

    Recom. back up fuse : 400-480V: 80 A, or 63 A "Slow" fuse (D characteristics outlets for motor starter, circuit breaker