Area of use / certification
Flow / Pressure / Volume
-
Tank Volume (ltr):
650
-
Hz v Q-max measure:
50
-
Q-max (l/min):
210
-
P-max (bar):
210
-
Flowrate1:
50 ltr/min @ 210 bar
-
Flowrate2:
70 ltr/min @ 150 bar
-
Flowrate3:
115 ltr/min @ 50 bar
-
Min. viscosity (cst):
15
-
Max. Viscosity (cst):
162
-
Start Viscosity (cst):
1618
Connections
-
Inlet connection:
1 ea 1" BSP
-
Outlet connection:
1 ea 1" BSP
Power supply
-
Fuse (A):
80
-
El.Power1:
380-415 D
-
(Hz):
50
-
(kW):
30
-
(A):
53
-
El.Power2:
660-720 Y
-
(Hz):
50
-
(kW):
30
-
(A):
31
-
El.Power3:
380-415 D
-
(Hz):
60
-
(kW):
30
-
(A):
54,6
-
El.Power4:
660-690 Y
-
(Hz):
60
-
(kW):
30
-
(A):
31,5
-
El.Power5:
440-480 D
-
(Hz):
60
-
(kW):
34.5
-
(A):
53,3
-
Starter:
Stahl 8264/222-3110-S,
EEx de IIBT6,
400-690 V 50-60 Hz
Filter
-
Filter outlet (qty):
1
-
Filterhouse (type):
Finnfilter FF 7008 F003 BK 35 GL24
-
Filterelement (type):
Finnfilter FC 7008 F003 BS/P169433/D143G03A
-
Filter inlet (qty):
1
-
Filterhouse (type):
Finnfilter FF 1302 F003 BK
-
Filterelement (type):
Finnfilter FC 1302 F003 BS/R432G03
Additional information
-
Equipment / Functions:
Flow indicator, heat exchanger and outlet for samples, level sensor.
Recom. back up fuse : 400-480V: 80 A, or 63 A "Slow" fuse (D characteristics outlets for motor starter, circuit breaker