Dimensions

  • Length(mm):
    2400
  • Width(mm):
    1400
  • Height(mm):
    1950
  • Weight (kg):
    1500
  • Lifting/ Transportation:
    Frame with forklift channels

Construction year

  • Built:
    1992
  • Upgraded/rebuilt:
    2008

Area of use / certification

  • Onshore/offshore:

    Onshore

Flow / Pressure / Volume

  • Tank Volume (ltr):
    1600
  • Hz v Q-max measure:
    50
  • Q-max (l/min):
    490
  • Hz v P-max measure:
    50
  • P-max (bar):
    200
  • Flowrate1:
    160 l/min @ 80 bar (50 Hz)
  • Flowrate2:
    80 l/min @ 200 bar (50 Hz)
  • Min. viscosity (cst):
    10
  • Max. Viscosity (cst):
    1000

Connections

  • Inlet connection:
    2 ea 1" BSP
  • Outlet connection:
    2 ea 1" BSP

Pump(s)

  • Pump1 (type):
    KPM K3VL 80/B - 1NRMM-L0/1-H3
  • Pump1 (Cert. No.):
    00200774
  • Pump2 (type):
    KPM K3VL 80/B - 1NRMM-L0/1-H3
  • Pump2 (Cert. No.):
    00200775

Motor / Engine(s)

  • Motor1 (type):
    Lönne 1TZ 95011EB
  • Motor2 (type):
    Lönne 14BG 186-4AA96-Z180L

Power supply

  • Fuse (A):
    125
  • El.Power1:
    400 VY
  • (Hz):
    50
  • (kW):
    22
  • (A):
    45
  • El.Power2:
    440 Y
  • (Hz):
    60
  • (kW):
    25
  • (A):
    41
  • El.Power3:
    460 Y
  • (Hz):
    60
  • (kW):
    22
  • (A):
    36
  • Starter:
    Industrial

Filter

  • Filter outlet (qty):
    2
  • Filterhouse (type):
    Finn Filter FF7008.Q010.BS35.GT24
  • Filterelement (type):
    Finn Filter FC7008.Q002.BK
  • Filter inlet (qty):
    4
  • Filterhouse (type):
    Finn Filter FF1148.Q010.BS35.GT24
  • Filterelement (type):
    Finn Filter FC7008.Q002.BK

Additional information

  • Equipment / Functions:

    Unit have also integrated two smaller pumps:

    Denison - T6CCM B22-B22 R001 - D100 Dobbel vinge (Motor: Lönne 7BA 160 M 04)

    Each pump can be driven individual, but all 4 together gives a max flow at 490 l/min.

    (Pump 1: 80 ltr/min @ 80 bar, Pump 2: 100 ltr/min @ 25 bar, Pump 1: 100 ltr/min @ 25 bar, Pump 1: 80 ltr/min @ 80 bar)

    2 ea immersion heaters in the tank, 2 ea. Flowindicator, airfilter for tank, level sensor