Dimensions

  • Length(mm):
    1400
  • Width(mm):
    900
  • Height(mm):
    1550
  • Weight (kg):
    600
  • Lifting/ Transportation:
    Frame with forklift channels and wheels.

Construction year

  • Built:
    1994

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIC T4 Zone 1. In acc. to Norsok Z-015

Flow / Pressure / Volume

  • Tank Volume (ltr):
    350
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    105
  • P-max (bar):
    210

Connections

  • Inlet connection:
    1 ea 1/2" BSP
  • Outlet connection:
    1 ea 1/2" BSP

Pump(s)

  • Pump1 (type):
    Denison PVT 29, Variable piston

Motor / Engine(s)

  • Motor1 (type):
    Teve Varnost 4KTC 160L-4 (Eexde IIC T4 IP-56)
  • Motor1 (Cert. No.):
    519

Power supply

  • Fuse (A):
    63
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    15
  • (A):
    30,1
  • El.Power2:
    660-720 VY
  • (Hz):
    50
  • (kW):
    15
  • (A):
    17,2
  • El.Power3:
    400 VD
  • (Hz):
    60
  • (kW):
    15
  • El.Power4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    17,3
  • (A):
    29,8
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    15
  • (A):
    14,8
  • Starter:

    ABB/CEAG Eexde IIC T6 IP-56 Ser. No: 21708

    400-690 V 50-60 Hz

Filter

  • Filter outlet (qty):
    1
  • Filterhouse (type):
    Parker 24P-2
  • Filterelement (type):
    GO 1316, D721G03A
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    Parker 24P-2
  • Filterelement (type):
    GO 1316, D721G03A

Additional information

  • Equipment / Functions:

    Flow indicator, heat exchanger and outlet for samples.

    Suitable for flushing of tubing.