Area of use / certification
Flow / Pressure / Volume
-
Tank Volume (ltr):
350
-
Hz v Q-max measure:
60
-
Q-max (l/min):
140
-
P-max (bar):
300
-
Flowrate1:
15 ltr/min @ 300 Bar
-
Flowrate2:
48 ltr/min @ 150 Bar
-
Flowrate3:
95 ltr/min @ 50 Bar
-
Min. viscosity (cst):
10
-
Max. Viscosity (cst):
1000
Connections
-
Inlet connection:
1 ea 1/2" BSP
-
Outlet connection:
1 ea 1/2" BSP
Filter
-
Filter outlet (qty):
1
-
Filterhouse (type):
FF 7007 F003 BK 35 GL 24
-
Filterelement (type):
D142603A
-
Filter inlet (qty):
1
-
Filterhouse (type):
FF 7007 F003 BK 35 GL 24
-
Filterelement (type):
D142603A
Additional information
-
Equipment / Functions:
Viscosity range between 200 – 1000 cst. requires heating without strain.
Pressure regulator, flowmeter, temperature indicator, outlet for samples, heat exchanger and manhole cover on top of tank.