Dimensions

  • Length(mm):
    1400
  • Width(mm):
    900
  • Height(mm):
    1600
  • Weight (kg):
    600
  • Lifting/ Transportation:
    Frame with forklift channels and wheels.

Construction year

  • Built:
    1998

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIB T4 Zone 1, In acc. to Norsok Z-015

Flow / Pressure / Volume

  • Tank Volume (ltr):
    350
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    140
  • P-max (bar):
    300
  • Flowrate1:
    15 ltr/min @ 300 Bar
  • Flowrate2:
    48 ltr/min @ 150 Bar
  • Flowrate3:
    95 ltr/min @ 50 Bar
  • Min. viscosity (cst):
    10
  • Max. Viscosity (cst):
    1000

Connections

  • Inlet connection:
    1 ea 1/2" BSP
  • Outlet connection:
    1 ea 1/2" BSP

Pump(s)

  • Pump1 (type):
    Denison PVT 29, Variable piston
  • Pump1 (Cert. No.):
    00271738

Motor / Engine(s)

  • Motor1 (type):
    Varnost 4KTC160-L-4 (EExde IIC T4)
  • Motor1 (Cert. No.):
    2865

Power supply

  • Fuse (A):
    63
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    15
  • (A):
    30
  • El.Power2:
    380-415 VD
  • (Hz):
    60
  • (kW):
    15
  • (A):
    29
  • El.Power3:
    660-720 VY
  • (Hz):
    50
  • (kW):
    15
  • (A):
    17,2
  • El.Power4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    17,3
  • (A):
    29,3
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    15
  • (A):
    16,7
  • Starter:
    Stahl Eexde IIC T5 (Ser. No: 79559) 400-690 V Max. load: 32 A 50-60 Hz

Filter

  • Filter outlet (qty):
    1
  • Filterhouse (type):
    FF 7007 F003 BK 35 GL 24
  • Filterelement (type):
    D142603A
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    FF 7007 F003 BK 35 GL 24
  • Filterelement (type):
    D142603A

Additional information

  • Equipment / Functions:

    Viscosity range between 200 – 1000 cst. requires heating without strain.

    Pressure regulator, flowmeter, temperature indicator, outlet for samples, heat exchanger and manhole cover on top of tank.