Dimensions

  • Length(mm):
    1940
  • Width(mm):
    1220
  • Height(mm):
    2080
  • Weight (kg):
    1750
  • Lifting/ Transportation:

    Frame with forklift channels and lifting slings.

    Slings and shackles in acc. to DNV 2.7-1. Frame in acc. to Machine directives 522.

    Ref. cert. frame : 30654/1

Construction year

  • Built:
    1998

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIB T4 zone 1, In acc. to Norsok Z-015

Flow / Pressure / Volume

  • Tank Volume (ltr):
    1200
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    460
  • P-max (bar):
    210
  • Min. viscosity (cst):
    10
  • Max. Viscosity (cst):
    160
  • Start Viscosity (cst):
    1600

Connections

  • Inlet connection:
    1 ea 1" BSP
  • Outlet connection:
    1 ea 1" BSP

Pump(s)

  • Pump1 (type):
    Denison P260 variable pressure compensated piston.

Motor / Engine(s)

  • Motor1 (type):
    Teve Varnost 3KTC225M-4 (Eexde IIB+H2 T4 IP-56)
  • Motor1 (Cert. No.):
    133

Power supply

  • Fuse (A):
    125
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    45
  • (A):
    81,5
  • El.Power2:
    660-720 VY
  • (Hz):
    50
  • (kW):
    45
  • (A):
    47
  • El.Power3:
    400 VD
  • (Hz):
    60
  • (kW):
    45
  • (A):
    81,5
  • El.Power4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    51,7
  • (A):
    80,9
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    45
  • (A):
    48
  • Starter:
    Stahl DOL Eexde (ia) IIC T5 (Ser. No: 81263) 400-690 V Max. load 85 A 50-60 Hz

Filter

  • Filter outlet (qty):
    2
  • Filterhouse (type):
    FF 7008 F003 BK
  • Filterelement (type):
    FC 7008 F003 BS / D143G03A
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    Finnfilter FK 1099 F003 BA 16 SX 32
  • Filterelement (type):
    Finnfilter FC 1099 F003 BS / R732G03P

Additional information

  • Equipment / Functions:

    Viscosity range between 200 – 1000 cst require heating without strain.

    Breathing filter : 1 ea. UCC UC:AB:10001

    Pressure regulator, effect regulator with remote control, flowmeter, temperature indicator, outlet for samples, heat exchanger and manhole cover on top of tank.