Construction year
-
Built:
1998
-
Upgraded/rebuilt:
2013
Area of use / certification
-
Onshore/offshore:
-
Standard:
Eexde IIC T4 Zone 1
Flow / Pressure / Volume
-
Tank Volume (ltr):
1000
-
Hz v Q-max measure:
60
-
Q-max (l/min):
480
-
P-max (bar):
320
-
Flowrate1:
85 l/min @ 320 bar (50 Hz)
-
Flowrate2:
110 l/min @ 250 bar (50 Hz)
-
Flowrate3:
180 l/min @ 150 bar (50 Hz)
-
Min. viscosity (cst):
10
-
Max. Viscosity (cst):
1000
Connections
-
Inlet connection:
2 ea 1" BSP
-
Outlet connection:
2 ea 1" BSP
Filter
-
Filter outlet (qty):
2
-
Filterhouse (type):
Pallfilter HH 9680C24UPRBO
-
Filterelement (type):
P169433/D143G03A
-
Filter inlet (qty):
1
-
Filterhouse (type):
Pallfilter HH 8420 D48UPVWD
-
Filterelement (type):
TXW 8C-10-B, 937741Q, 937777Q
Additional information
-
Equipment / Functions:
Q-MAX IS TOTAL FLOW FOR BOTH PUMPS (PUMP 1: 240 ltr/min - PUMP 2: 240 ltr/min).
Viscosity rangebetween 200 – 1000 cst. require heating without strain.
Heat exchanger, flow indictor, level switch, outlet for samples, cover on top of tank and bypass testline, Level sensor
Both pumps can be driven separately and at the same time.