Dimensions

  • Length(mm):
    2250
  • Width(mm):
    1550
  • Height(mm):
    1850
  • Weight (kg):
    1200
  • Lifting/ Transportation:
    Frame with forklift channels

Construction year

  • Built:
    1992

Area of use / certification

  • Onshore/offshore:

    Onshore

Flow / Pressure / Volume

  • Tank Volume (ltr):
    500
  • Hz v Q-max measure:
    50
  • Q-max (l/min):
    190
  • Hz v P-max measure:
    50
  • P-max (bar):
    210
  • Min. viscosity (cst):
    15
  • Max. Viscosity (cst):
    75

Connections

  • Inlet connection:
    2 ea 1" BSP and 1 ea 1/2" BSP
  • Outlet connection:
    2 ea 1" BSP and 3 ea 1/2" BSP

Pump(s)

  • Pump1 (type):
    Axial piston Vickers F3-PV130-P-R-1-1/11/HP
  • Pump2 (type):
    Pinion Dowty 2PL 090 CPDFBN

Motor / Engine(s)

  • Motor1 (type):
    VEM KPER 180 L4 (380V 50Hz 43,5 Amp 22 kW / 220V 50Hz 74 Amp 22 kW)
  • Motor2 (type):
    VEM KMER 100 L4 (380V 50Hz 5,6 Amp 2,2 kW / 220V 50Hz 9,6 Amp 2,2 kW)

Power supply

  • Fuse (qty):
    1
  • Fuse (A):
    80
  • El.Power1:
    Pump 1: 380 V
  • (Hz):
    50
  • (A):
    80
  • El.Power2:
    Pump 2: 380 V
  • (Hz):
    50
  • (A):
    32
  • El.Power3:
    Pump 3: 380 V
  • (Hz):
    50
  • (A):
    16
  • Starter:
    Industrial

Filter

  • Filter outlet (qty):
    2
  • Filterhouse (type):
    FF 7008 Q010.BS35.GT.24
  • Filterelement (type):
    FC 7008.Q010.BK
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    Parker FK 1093 Q010.BA16.GX24
  • Filterelement (type):
    FC 1093 Q003.BS / R726G03P

Additional information

  • Equipment / Functions:

    Unit is q/w 3 pumps:

    Pump 1 (Axial piston Vickers F3-PV130-P-R-1-1/11/HP): 190 ltr/min / 210 bar (El. Power: 80A, 380V, 50 Hz)

    Pump 2 (Pinion Truninger QT25-005 R/VFM): 7 ltr/min / 350 bar (El. Power: 32A, 380V, 50 Hz)

    Motor for pump 2: VEM KMER 132 S4 (380V 50Hz 12,5 Amp 5,5 kW / 220V 50Hz 21 Amp 5,5 kW)

    Pump 3 (Pinion Dowty 2PL 090 CPDFBN: 40 ltr/min / 10 bar) (El. Power 16A, 38+V, 50Hz

    Pump 2 is a high-pressure pump with separate outlet (common return).

    Level switch and. temp. switch. Permanent UCC monitor with temp., pressure and flow.