Dimensions

  • Length(mm):
    1700
  • Width(mm):
    800
  • Height(mm):
    1850
  • Weight (kg):
    600
  • Lifting/ Transportation:
    Frame with forklift channels

Construction year

  • Built:
    1995

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Eexde IIC T4 zone 1, In acc. to Norsok Z-015

Flow / Pressure / Volume

  • Tank Volume (ltr):
    350
  • Hz v Q-max measure:
    60
  • Q-max (l/min):
    110
  • P-max (bar):
    210
  • Flowrate1:
    45 ltr/min @ 210 Bar (50 Hz)
  • Flowrate2:
    95 ltr/min @ 100 Bar (50 Hz)
  • Flowrate3:
    105 ltr/min @ 50 Bar (50 Hz)
  • Min. viscosity (cst):
    10
  • Max. Viscosity (cst):
    160
  • Start Viscosity (cst):
    1600

Connections

  • Inlet connection:
    1 ea 1/2" BSP
  • Outlet connection:
    1 ea 1/2" BSP

Pump(s)

  • Pump1 (type):
    Denison PVT-29

Motor / Engine(s)

  • Motor1 (type):
    Bartec Varnost 4KTC 180 M-4 II2G EEx de IIC T4 IP56 (Cert. No: PTB 05 ATEX 1054)
  • Motor1 (Cert. No.):
    200833454

Power supply

  • Fuse (A):
    63
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    18,5
  • (A):
    35,3
  • El.Power2:
    660-720 VY
  • (Hz):
    50
  • (kW):
    18,5
  • (A):
    20,4
  • El.Power3:
    380-415 VD
  • (Hz):
    60
  • (kW):
    18,5
  • (A):
    36,3
  • El.Power4:
    660-690 VY
  • (Hz):
    60
  • (kW):
    18,5
  • (A):
    21
  • El.Power5:
    440-480 VD
  • (Hz):
    60
  • (kW):
    21,3
  • (A):
    35,2
  • Starter:

    Ceag GHG 6645 (Ser. No: 41328)

    Eexde IIC T5 IP-65

    400-690 V 50-60 Hz Max load: 125 A

Filter

  • Filter outlet (qty):
    1
  • Filterhouse (type):
    Parker 70T210QBPKG201
  • Filterelement (type):
    D141G03A/P167842/938777Q
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    Parker RF-22
  • Filterelement (type):
    PARKER 932692Q

Additional information

  • Equipment / Functions:
    Flowmeter, manometer, level glass, thermometer, sampling