Area of use / certification
Flow / Pressure / Volume
-
Tank Volume (ltr):
350
-
Hz v Q-max measure:
60
-
Q-max (l/min):
110
-
P-max (bar):
210
-
Flowrate1:
45 ltr/min @ 210 Bar (50 Hz)
-
Flowrate2:
95 ltr/min @ 100 Bar (50 Hz)
-
Flowrate3:
105 ltr/min @ 50 Bar (50 Hz)
-
Min. viscosity (cst):
10
-
Max. Viscosity (cst):
160
-
Start Viscosity (cst):
1600
Connections
-
Inlet connection:
1 ea 1/2" BSP
-
Outlet connection:
1 ea 1/2" BSP
Pump(s)
-
Pump1 (type):
Denison PVT-29
Power supply
-
Fuse (A):
63
-
El.Power1:
380-415 VD
-
(Hz):
50
-
(kW):
18,5
-
(A):
35,3
-
El.Power2:
660-720 VY
-
(Hz):
50
-
(kW):
18,5
-
(A):
20,4
-
El.Power3:
380-415 VD
-
(Hz):
60
-
(kW):
18,5
-
(A):
36,3
-
El.Power4:
660-690 VY
-
(Hz):
60
-
(kW):
18,5
-
(A):
21
-
El.Power5:
440-480 VD
-
(Hz):
60
-
(kW):
21,3
-
(A):
35,2
-
Starter:
Ceag GHG 6645 (Ser. No: 41328)
Eexde IIC T5 IP-65
400-690 V 50-60 Hz Max load: 125 A
Filter
-
Filter outlet (qty):
1
-
Filterhouse (type):
Parker 70T210QBPKG201
-
Filterelement (type):
D141G03A/P167842/938777Q
-
Filter inlet (qty):
1
-
Filterhouse (type):
Parker RF-22
-
Filterelement (type):
PARKER 932692Q
Additional information
-
Equipment / Functions:
Flowmeter, manometer, level glass, thermometer, sampling