Dimensions

  • Length(mm):
    1500
  • Width(mm):
    1100
  • Height(mm):
    1410
  • Weight (kg):
    1350
  • Lifting/ Transportation:
    Frame with forklift channels and wheels (Ref. serial no. frame : FU-62)

Construction year

  • Built:
    2009

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Offshore Zone 1, In acc. to: Norsok Z-015, ATEX

Flow / Pressure / Volume

  • Tank Volume (ltr):
    300
  • Hz v Q-max measure:
    50
  • Q-max (l/min):
    95
  • P-max (bar):
    210
  • Flowrate1:
    60 ltr/min @ 210 Bar (50 Hz)
  • Flowrate2:
    95 ltr/min @ 150 Bar (50 Hz)
  • Flowrate3:
    95 ltr/min @ 100 Bar (50 Hz)
  • Min. viscosity (cst):
    12
  • Max. Viscosity (cst):
    100
  • Max temp. (GrC):
    55

Connections

  • Inlet connection:
    1 ea 1/2" BSP
  • Outlet connection:
    1 ea 1/2" BSP

Pump(s)

  • Pump1 (type):

    Moog RKP-II Radial Piston Pump HKR18

    D954K224710RKP063KC21S2 Y00

    II --/2 GD IIA

  • Pump1 (Cert. No.):
    BVS06ATEXHB052

Motor / Engine(s)

  • Motor1 (type):
    ATB BD200L-4 (Ser. No: 491717001) EEx de IIB T4 IP 56
  • Motor1 (Cert. No.):
    PTB99 ATEX 1091

Power supply

  • Fuse (A):
    63
  • El.Power1:
    400 VD
  • (Hz):
    50
  • (kW):
    30
  • (A):
    53
  • El.Power2:
    690 VY
  • (Hz):
    50-60
  • (kW):
    30
  • (A):
    31
  • El.Power3:
    400 VD
  • (Hz):
    60
  • (kW):
    30
  • (A):
    52
  • El.Power4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    34,5
  • (A):
    55-51
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    30
  • (A):
    32-30
  • Starter:

    GHG 6645 (Ser. No: 09-001)

    EEx de IIC T6 PTB 98 ATEX 1054U

    NEMKO No: 09ATEX2074

Filter

  • Filter outlet (qty):
    1
  • Filterhouse (type):
    FF7006.Q010.BS35.GT20 (400 Bar MWP)
  • Filterelement (type):
    FC7006.Q010.BK / D721G03A
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    Parker FF1146.Q010.BS35.GT20 (40 Bar MWP)
  • Filterelement (type):
    FC7006.Q010.BK / D721G03A

Additional information

  • Equipment / Functions:

    Recommended viscosity: 16 – 46 cst.

    Recom. max back up fuse:

    660-690V: 63 A

    400-480V: 63 “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)

    Heat exchanger, Flowindicator, pressure regulator, pressuregauge, level glass, level guard, thermometer, breathing filter on tank, manhole, Sampling hangs on a separate BSP 1 "welded in unit so that you can take on sampling on the return line.