Dimensions

  • Length(mm):
    1500
  • Width(mm):
    1100
  • Height(mm):
    1883
  • Weight (kg):
    1000
  • Lifting/ Transportation:
    Frame with forklift channels and wheels (Ref. serial no. frame : FU-67)

Construction year

  • Built:
    2011

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Z-015 (type):
    U99
  • Standard:

    Offshore Zone 1, Z-015

    ATEX II2G EEx de IIB T4

Flow / Pressure / Volume

  • Tank Volume (ltr):
    300
  • Hz v Q-max measure:
    50
  • Q-max (l/min):
    116
  • P-max (bar):
    350
  • Flowrate1:
    10 ltr/min @ 350 Bar (50 Hz)
  • Flowrate2:
    40 ltr/min @ 250 Bar (50 Hz)
  • Flowrate3:
    115 ltr/min @ 100 Bar (50 Hz)
  • Min. viscosity (cst):
    12
  • Max. Viscosity (cst):
    100

Connections

  • Inlet connection:
    1 ea 1/2" BSP Male
  • Outlet connection:
    1 ea 1/2" BSP Male

Pump(s)

  • Pump1 (type):

    MOOG HKR15A1 Radial Piston Pump ( Serial No: DA78886)

    RKP080TM35S2Z30

    Ex II -/2 GD 135ºC (T4) -15ºC ≤ T0 ≤ +60ºC

  • Pump1 (Cert. No.):
    BVS06ATEXHB052

Motor / Engine(s)

  • Motor1 (type):
    Bartec Varnost 3KTC 200 L-4 30kW (Serial No: 201157045) EEx de IIB T4 IP 56
  • Motor1 (Cert. No.):
    PTB 00 ATEX 1080

Power supply

  • Fuse (A):
    63
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    30
  • (A):
    53
  • El.Power2:
    660-720 VY
  • (Hz):
    50
  • (kW):
    30
  • (A):
    31
  • El.Power3:
    380-415 VD
  • (Hz):
    60
  • (kW):
    30
  • (A):
    54,6
  • El.Power4:
    440-480 VD
  • (Hz):
    60
  • (kW):
    34,5
  • (A):
    53,3
  • El.Power5:
    660-690 VY
  • (Hz):
    60
  • (kW):
    30
  • (A):
    31,5
  • Starter:

    Ex II 2G EExd e IIB

    Kema 01 ATEX 2145U

    NEMKO Nr: Nemko 11ATEX2037

Filter

  • Filter outlet (qty):
    1
  • Filterhouse (type):
    FF7006.Q010.BS35.GT20D
  • Filterelement (type):
    FC7006.Q010.BK / P167842 / D141G03A
  • Filter inlet (qty):
    1
  • Filterhouse (type):
    17445M210QBPKG201
  • Filterelement (type):
    FC7006.Q010.BK / P167842 / D141G03A

Additional information

  • Equipment / Functions:

    Recommended viscosity: 16 – 46 cst.

    Recom. back up fuse:

    660-690V: 63 A

    400-480V: 63A ”slow” fuse (D-characteristic, conn. for motorstarter, effect switch)

    Heat exchanger, Flowindicator, pressure regulator, pressure gauge, level glass, level guard, thermometer, breathing filter on tank, man hole, drip tray with drain coupling, 1” BSP male on drain of tank