Area of use / certification
-
Onshore/offshore:
-
Z-015 (type):
U99
-
Standard:
Offshore Z-015 Zone 1
ATEX II 2G Ex de IIB T4
ATEX II 2G C IIB T4
Flow / Pressure / Volume
-
Tank Volume (ltr):
300
-
Hz v Q-max measure:
50
-
Q-max (l/min):
117
-
P-max (bar):
350
-
Flowrate1:
20 ltr/min @ 350 Bar (50 Hz)
-
Flowrate2:
55 ltr/min @ 250 Bar (50 Hz)
-
Flowrate3:
100 ltr/min @ 150 Bar (50 Hz)
-
Min. viscosity (cst):
12
-
Max. Viscosity (cst):
100
-
Max temp. (GrC):
60
Connections
-
Inlet connection:
1 ea 1" BSP Male
-
Outlet connection:
1 ea 1" BSP Male
Pump(s)
-
Pump1 (type):
MOOG HKR15A1 (Serial no DA46588)
RKPO80TM35S2Z30
Ex II 2GD 135°C (T4)
-
Pump1 (Cert. No.):
BVS 06 ATEX H/B 052
Additional information
-
Equipment / Functions:
Recommended viscosity: 16 – 46 cst.
Recom. back up fuse:
660-690V: 63 A
400-480V: 63 “slow” fuse (D-characteristic, outlet for motorstarter, circuit-breaker)
Heat exchangers, flow meters, manhole on top of tank, level gauge, level switch