Construction year
-
Built:
2001
-
Upgraded/rebuilt:
2022
Area of use / certification
-
Onshore/offshore:
-
Standard:
Zone 1, Z-015
Flow / Pressure / Volume
-
Q-max (m3/min):
24.4
-
Max vacuum:
0,9 Bar Vacuum
Connections
-
Inlet connection:
1 ea. 4” Camlock male
-
Outlet connection:
1 ea. 4" Camlock female
Pump(s)
-
Pump1 (type):
Samson Truckmaster 1600
-
Pump1 (Cert. No.):
11-21-LP035864-2
Motor / Engine(s)
-
Motor1 (type):
ABB M3KP 200 MLA 4
Demko 20 ATEX 2248 X
Ex db eb II B T4 Gb
-
Motor1 (Cert. No.):
3G1P212400788
Power supply
-
Power (Electrical/Air):
Electrical
-
Fuse (qty):
1
-
Fuse (A):
63
-
El.Power1:
400 VD
-
(Hz):
50
-
(kW):
30
-
(A):
54,8
-
El.Power2:
400 VD
-
(Hz):
60
-
(kW):
30
-
(A):
53,4
-
El.Power3:
440-480 VD
-
(Hz):
60
-
(kW):
30
-
(A):
49,5-46,8
-
El.Power4:
690 VY
-
(Hz):
50
-
(kW):
30
-
(A):
31,9
-
El.Power5:
660-690 VY
-
(Hz):
60
-
(kW):
30
-
(A):
32,4-31
-
Starter:
Gexys AS (Ser. No: 2009/3406/1)
EEx de IIC T6 IP66 (Cert. Nr: 09 ATEX 52184X)
690V 63A
Additional information
-
Equipment / Functions:
Recom. back-up fuse :
660V-690V: 63A
400v-480V: 63A "slow" fuse (D-characteristic, outlet for motorstarter, circuitbreaker)
- Light
- Gauge
Must be coupled to vacuumtank (VS-20B), and an optional mud-tank (skip). Standard volume of skip is 2700 litres.
Inlet coupling can also be used to blow with, but do NOT use exhaust coupling to blow with, this line does not have a safetyvalve.