Construction year
-
Built:
1998
-
Upgraded/rebuilt:
2022
Area of use / certification
-
Onshore/offshore:
-
Standard:
Zone 2, Z-015
Flow / Pressure / Volume
-
Q-max (m3/min):
24.4
-
Max vacuum:
0,9 Bar Vacuum
Connections
-
Inlet connection:
1 ea. 4” Camlock male
-
Outlet connection:
1 ea. 4" Camlock female
Power supply
-
Power (Electrical/Air):
Electrical
-
Fuse (qty):
1
-
Fuse (A):
63
-
El.Power1:
400 VD
-
(Hz):
50
-
(kW):
37
-
(A):
65,0
-
El.Power2:
690 VY
-
(Hz):
50
-
(kW):
37
-
(A):
37,5
-
El.Power3:
400 VD
-
(Hz):
60
-
(kW):
37
-
(A):
67,0
-
El.Power4:
440-480 VD
-
(Hz):
60
-
(kW):
43
-
(A):
68,0-62,0
-
El.Power5:
660-690 VY
-
(Hz):
60
-
(kW):
37
-
(A):
41,0-39,0
-
Starter:
MES 22-007
DNV 22 ATEX 33782 X
II2G (1) G Ex db eb [ia Ga] IIC T4 Gb
Additional information
-
Equipment / Functions:
Recom. back-up fuse :
660V-690V: 63A
400v-480V: 63A "slow" fuse (D-characteristic, outlet for motorstarter, circuitbreaker)
- Light
- Gauge
Must be coupled to vacuumtank (VS-21B), and an optional mud-tank (skip). Standard volume of skip is 2700 litres.
Inlet coupling can also be used to blow with, but do NOT use exhaust coupling to blow with, this line does not have a safetyvalve.