Dimensions

  • Length(mm):
    2991
  • Width(mm):
    2438
  • Height(mm):
    2591
  • Weight (kg):
    2190
  • Lifting/ Transportation:
    Frame with forklift channels and lifting slings. DNV 2.7-1 /DNV 2.7-2 Tara 2300 Kg - Payload 5700 Kg - MGW 8000 Kg
  • Certificate(s) / Serial No::
    195126/VS-39

Construction year

  • Built:
    2019

Area of use / certification

  • Onshore/offshore:

    Offshore

  • Standard:
    Zone 1, Z-015

Flow / Pressure / Volume

  • Q-max (m3/min):
    1015
  • Max vacuum:
    0,86 Bar Vacuum

Connections

  • Inlet connection:
    1 ea. 4” Camlock male Connection water/operations : 1” claw coupling (minimum 2 Bar with freshwater)
  • Outlet connection:

    Connection exhaust : 1 ea. 4” Camlock male

    Connection drainage : 1 ea. 4” Camlock male

    Connection water out: 1 ea. 1” claw coupling

Pump(s)

  • Pump1 (type):
    Samson KS1025
  • Pump1 (Cert. No.):
    04-24-LP046217

Motor / Engine(s)

  • Motor1 (type):
    Hoyer 7AT 200LA-2 IP55 EEx de IIB T4 Cert. No: Bas.no.Ex97D1111X
  • Motor1 (Cert. No.):
    GX032148

Power supply

  • Power (Electrical/Air):
    Electrical
  • Fuse (qty):
    1
  • Fuse (A):
    63
  • El.Power1:
    380-415 VD
  • (Hz):
    50
  • (kW):
    30
  • (A):
    69-63
  • El.Power2:
    440-480 VD
  • (Hz):
    60
  • (kW):
    43
  • (A):
    70-64
  • El.Power3:
    660-690 VY
  • (Hz):
    50
  • (kW):
    37
  • (A):
    40-38
  • El.Power4:
    660-690 VY
  • (Hz):
    60
  • (kW):
    33-35
  • (A):
    39
  • Starter:
    EEx de IIC T6 IP66 Sert. Nr: 09 ATEX 52184X 690V 63A Nemko Nr: 93.381

Additional information

  • Equipment / Functions:

    230v 1fas EX-ovn for frostsikring. Separat tilførsel

    Recom. back-up fuse :

    660V-690V: 63A

    400v-480V: 63A "slow" fuse (D-characteristic, outlet for motorstarter, circuitbreaker)

    - Light

    - Pressure gauge

    - Heater

    Must be coupled to vacuumtank, and an optional mud-tank (skip).

    Standard volume of skip is 2700 litres. Couple these together as shown in example below.

    Inlet coupling can also be used to blow with, but do NOT use exhaust coupling to blow with, this line does not have a safetyvalve.